Title: Justification of Energy Conservation in the Drying Part During the Modernization of Circulation Bearing Lubrication
Authors: Sivakov, V. P.
Vurasko, A.
Isakov, S. N.
Isaeva, K. S.
Issue Date: 2024
Publisher: Pleiades Publishing
Citation: Justification of Energy Conservation in the Drying Part During the Modernization of Circulation Bearing Lubrication / V. P. Sivakov, A. Vurasko, S. N. Isakov, K. S. Isaeva // Theoretical Foundations of Chemical Engineering. – 2024. – Vol. 58. – Iss. 4. – P. 1428-1434. DOI: 10.1134/S0040579525600391.
Sivakov, V. P., Vurasko, A. V., Isakov, S. N., & Isaeva, K. S. (2024). Justification of energy conservation in the drying part during the modernization of circulation bearing lubrication. Theoretical Foundations of Chemical Engineering, 58(4), 1428–1434. doi:10.1134/s0040579525600391
Abstract: The purpose of this work was to justify the application of a less energy-intensive circulation lubrication system from two options for the installation of rotameter blocks: compact (with one block of rotameters installed on the front and drive sides of the drying section) and distributed (with four blocks of rotameters installed on the front and drive sides of the drying section). To achieve this goal, the following tasks were addressed: measuring and analyzing the temperature of the operating compact circulation lubrication system of the drying cylinders and fabric-leading rolls in the drying section; calculating the length of small diameter tubes with an internal diameter of d<inf>in</inf> = 8 mm for oil supply from the rotameters to the bearings of the drying cylinders and fabric-leading rolls for both the operating (compact) and group-distributed installations of rotameters in the drying section; determining the heat loss carried away by the circulating oil from the zone of the thermal insulation hood of the drying section during the operation of both the compact and group-distributed installations of rotameters. Experimental studies have shown that the temperature of the oil in the tubes with the compact installation of the rotameters increases by 27 to 29°C from the entry into the thermal insulation hood zone of the drying section to the entry into the bearing supports of the drying cylinders and fabric-leading rolls, reaching an average of 67°C. The calculated length of the oil supply tubes to the bearing supports when the rotameters are positioned before the drying groups is shorter than the corresponding tube length in the compact arrangement of the rotameters by 1501.52 m. Reducing the length of the tubes in the thermal insulation hood zone of the drying section under the established operating conditions significantly reduces the heating of the oil and the transfer of thermal energy from the paper drying zone. A calculation was performed to determine the reduction in the amount of heat carried away from the drying section when the rotameters are arranged in groups compared to the compact arrangement. It was established that over 1 h of operation of the drying section, the amount of heat carried away by the heated oil decreases by 74 844 kJ. © Pleiades Publishing, Ltd. 2024.
Keywords: DRYING CYLINDER
DRYING SECTION
HEAT LOSSES
KEYWORDS: CIRCULATION LUBRICATION
TEMPERATURE DIAGNOSTICS
AIR LUBRICATION
HIGH MODULUS TEXTILE FIBERS
RESEARCH LABORATORIES
DRYING CYLINDER
DRYING SECTION
ENERGY
INSULATION HOOD
KEYWORD: CIRCULATION LUBRICATION
LUBRICATION /
LUBRICATION SYSTEM
OIL SUPPLIES
TEMPERATURE DIAGNOSTICS
THERMAL
HEAT LOSSES
URI: https://elar.usfeu.ru/handle/123456789/14519
DOI: 10.1134/S0040579525600391
SCOPUS: 2-s2.0-105000335062
WoS: WOS:001447116700015
RSCI: 80498791
EDN: FWYSEM
Appears in Collections:Научные публикации, проиндексированные в SCOPUS и WoS CC

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.